Sinopts safety control gas magnet valve
You are here: Home » Products » Magnet valve » Sinopts safety control gas magnet valve

PRODUCT DETAIL

Sinopts safety control gas magnet valve

loading

Share to:
sharethis sharing button
Application:General
Material:Brass, Ceramic and plastic
Temperature of Media:Normal Temperature
Pressure:Low Pressure
Power:Solenoid
Media:Gas
Structure:Safety
Standard or Nonstandard:Standard
Product name:Magnet valve
Certificate:CE/IS09001/CSA/AGA/UL
  • SNM-208

  • SINOPTS or OEM

Availability:

1. Thermocouple and magnetic valve composegas safety protection devices, thermocouple is a transducercan provide the power, magnetic valve is a controller.,
2. When thermocouple tips is heated by fire, cold and heat generate thermoelectric power due to temperature difference, to form closed loop current and make magneticvalve actuation,opening gas path.
3. When the flame is out owing to unexpected reasons, thermocouple rapidly lose potential, magnet valve lose suction under the action of spring, so close gas path, and play a safety protection role.